Esthetic

 

REcommended Firing parameters!
Temperatures can vary due to different furnace performances.

Staining / Internal staining technique
  Start temp. Dry time Heat time Final temp. Holdt Vaccum Appearance
Stain 1
842°F
4 Min.

131°F/Min.

1436°F

1 Min.
-----
 
Stain 2
842°F
4 Min.
131°F/Min.
1436°F
1 Min.
-----
 
Glaze 1
842°F
4 Min.
131°F/Min.

1436°F

1 Min.
-----
Slightly shiny
Glaze 2
842°F
4 Min.
131°F/Min.
1436°F
1 Min.
-----
Shiny
Layering technique
  Start temp. Dry time Heat rate Final temp. Hold Vaccum Appearance
Connection
842°F
4 Min.
131°F/Min.
1454°F
1 Min.
YES
Shiney
Dentin 1
842°F
6 Min.
131°F/Min.
1436°F
1 Min.
YES
Slightly shiny
Dentin 2
842°F
6 Min.
131°F/Min.
1418°F
1 Min.
YES
Slightly shiny
Glaze without powder
842°F
4 Min.
131°F/Min.

1436°F

1 Min.
-----
Slightly shiny
Glaze with powder
842°F
4 Min.
131°F/Min.
1400°F
1 Min.
-----
Shiny